Insights

ISASecure and IEC 62443, explained with the numbers

What each certification program actually evaluates, how the security levels and device types change the scope, and where the common points of confusion come from — written by the assessors who run these evaluations.

Filteractive

7 articles match your filters

SSAIntermediate

One certificate, several levels: how ISASecure SSA assigns a capability security level per zone

How ISASecure SSA assigns an IEC 62443 capability security level to each zone of a system, why one certificate can carry several levels, and how to specify it.

Sep 8, 20268 min readRead
SSAIntermediate

IEC 62443-3-3 requirements: how ISASecure SSA evaluates all 100 clauses in FSA-S

ISASecure SSA's FSA-S stream covers every clause of IEC 62443-3-3: 51 system requirements and 49 enhancements, laid out as 116 rows and scored zone by zone.

Sep 8, 20268 min readRead
SSAIntermediate

How to read an ISASecure SSA certificate and report: zones, levels and user-enforced mitigations

How to read an ISASecure SSA certificate and its SSA-303 report: capability levels per zone, the ten report sections, and the mitigations the user must apply.

Sep 8, 20269 min readRead
SSAIntermediate

SSA SDA-S artifacts: the 74 lifecycle rows ISASecure checks for a system, and why fuzz and load results are among them

ISASecure SSA's SDA-S stream re-checks 74 assessable rows of the SDLA-312 lifecycle catalogue for the system as sold, fuzz and load coverage included.

Sep 8, 20268 min readRead
SSAIntermediate

A system as sold: IEC 62443-3-3 system certification scope under ISASecure SSA, and what falls outside it

ISASecure SSA certifies a control-system product as sold, at a version, in a fixed or scalable layout: the four eligibility criteria and what falls outside.

Sep 8, 20268 min readRead
SSAIntermediate

ISASecure SSA vulnerability testing: the scan where each zone sets its own pass threshold

How VIT-S works in ISASecure SSA: one known-vulnerability scan of every IP-addressed component, with the pass threshold set per component by its zone's level.

Sep 8, 20268 min readRead
SSAIntermediate

Independent testing in ISASecure SSA: eleven flagged requirements, one scan, one reference system

ISASecure SSA flags 11 of its 116 assessable rows for lab testing, plus one vulnerability scan on one reference system. What the lab tests and reviews.

Sep 8, 20269 min readRead

Have a product or system to certify?